1 Hour Fire Rated Wood Roof Ceiling Assembly
Floor or roof 1 hour.
1 hour fire rated wood roof ceiling assembly. 2 x 10 rafters 24 o c. 6 usg fire resistant assemblies test certiļ¬cation test conditions and fire and sound tested assemblies listed in this selector are based on characteristics properties and performance certificationof materials and systems obtained under controlled test conditions as set forth in the appropriate astm standard in effect at the time of test. Ul p533 roof ceiling one layer 5 8 15 9 mm fire shield c ga rc 2603 wallboard attached to 1 2 12 7 mm resilient furring channel spaced 12 o c. In fact there is no.
Gypsum wallboard roof ceilings wood framing pitched roof truss 11 1 hr. Screw fastened perpendicular to lower chord of wood trusses of 2 x 4 38 mm x 89 mm. What you ll eventually learn is that the easiest place to design your own 1 hour assembly is section 721 6 of the international building code. 276 fire rated ceiling assemblies suspension ceiling designs floor ceiling designs a003 3 hr.
Our range of drawings can help pros plan projects more effectively by utilizing designs for a fire rated ceiling assembly. Fire rated assemblies are listed in the fire resistance design manual published by the gypsum association. Concrete with cellular steel 3 hr. These listings are short summaries to serve as a.
Framing nominal 2x4 wood studs spaced 16 in. 12 x 24 2 x 4 8 w10 x 25 beam floor units and beam support 3 hr. No minimum joist size is given except that it needs to be adequate for structural loads. Ul does not appear to list an assembly as described.
Urb concealed grid system and tile. Floor ceiling assemblies here you can find drawings for our ul fire rated floor assemblies and ul fire rated ceiling assemblies. Fire rated wood frame wall and floor ceiling assemblies 5 ws4 1 1 one hour fire resistive wood frame wall assembly 2x4 wood stud wall 100 design load astm e 119 nfpa 251. I would like to apply the drywall directly to the bottom of the truss and also have insulation for sound control.
Substrate roof floor ceiling time assembly ff file no. Ibc section 722 6 could be used to calculate up to a 1 hour rating for a wood frame wall floor or roof assembly. Is this possible without using channels and what ul number would i use. O c double top plates single bottom plate.
Architects and contractors can spend a lot of time hunting for miscellaneous fire rated assemblies in wood construction. 2 1 3 4 2. Fire rated suspended ceiling wood truss council of america floor or roof fire notes 1. W 1 2 plywood span 17 live load 20lbs.
Assemblies include ducts dampers lighting or other fixtures in the tested assembly.